NexVDO Solutions · Medical imaging
Capture and record inside clinical imaging workflows.
Deploy capture, recording, and on-device analysis across operating rooms, endoscopy suites, and ultrasound carts without sending patient video off premises.
NexVDO Solutions · Medical imaging
Why edge for medical imaging
Keep patient video on premises
Analysis runs on the edge system inside the clinical network. Patient video does not leave the room to reach a model, which keeps identifiable footage inside the boundary your own controls already cover. Regulatory classification of the finished device, and any HIPAA or MDR obligations that follow, remain with the party placing it on the market.
Speak the hospital’s protocols
DICOM format support, PACS and WORKLIST server integration, and HL7 services ship in the SDK, so interoperability is not an export step bolted on later.
Keep the latency path short
Live surgical video rides SkyLink X, YUAN’s proprietary low-latency transmission protocol. Latency figures await publication.
Proven patterns
Start with the camera job. Pair the modules with real hardware.
Each pattern below names the SDK modules it needs and the YUAN Edge hardware it runs on.
HL7 hospital-system messaging
Exchange patient and order information over the five HL7 services in the SDK: Patient Query QRY_A19, Patient Query ADR_A19, Laboratory Results ORU_R01, Patient ADT Management, and Clinical Orders OMG_O19.
Capture → process → output
From imaging head to hospital system.
An ultrasound, endoscopy, or room-camera source enters through SC710N1 or SC750N1 M.2 capture cards mounted in the edge system. NexVDO Capture moves frames into the processing path. Record writes the procedure file with DICOM format support, and PACS, WORKLIST, and HL7 integration connects the recording to hospital information systems. Stream carries live surgical video over SkyLink X. HSB Holoscan bridges convert professional video into NVIDIA Holoscan-ready streams where that path applies.
Published ingest, interoperability, and hardware facts for a clinical imaging pipeline. Unpublished detail remains marked.
| Pipeline job | Published path | Hardware | SDK module | Status |
|---|---|---|---|---|
| Source ingest | HDMI, 12G-SDI from imaging systems | SC710N1 / SC750N1 M.2 capture | Capture | Published |
| Procedure recording | DICOM format, PACS, WORKLIST | VPP6N0-S-W NX | Capture + Record | Published |
| Hospital messaging | HL7: QRY_A19, ADR_A19, ORU_R01, ADT, OMG_O19 | VPP6N0-S-W NX | Capture | Published |
| Low-latency delivery | SkyLink X | VPP6N0-S-W NX | Stream | Latency figures — pending publication |
| On-device analysis | Detection, segmentation, feature matching | VPP6N0-S-W NX | Analysis | Published |
| Holoscan sensor bridging | HDMI / 12G-SDI to NVIDIA Holoscan streams | HSB Holoscan bridges | Capture | Bridge SKU scope — pending publication |
YUAN Edge hardware
Every pattern runs on named hardware
The systems and capture families above come from the YUAN Edge lineup — review them together before your evaluation.
See YUAN Edge hardwareBuild resources
Published material stays with the supported evaluation path. Missing artifacts stay visible as honest states.
- published with evaluation access
Sample pairings
Capture hardware, edge systems, and SDK modules arranged by pipeline job.
- in preparation
Reference architecture
A signal-to-output architecture for this vertical.
Documentation status
Regulatory, datasheet, licensing, and warranty documents with their current availability.
See the documentation library
Related solutions
Keep moving through the map
Need a human?
Engineers answer evaluation requests within 48 hours. Business and hardware questions route to Neteon, YUAN’s U.S. front door.
Evaluate on real hardware
Request an evaluation and get a substantive answer from an engineer within 48 hours. Evaluation hardware ships from U.S. stock.
- Engineer reply in 48h
- Ships from U.S. stock
- Free with YUAN hardware